Implementation Removal

Interlock Defeat


Safety

BSM 56 working levels increased.
Implementation: Number:
2024-11-07 18:29:00 2024-507

Ryan Anderson

Removed
Estimated Duration:
1 days

For BL1U production. Defeat is in place until default levels set to match.

2

Back of Rack A in DCR







DCR defeat board.

Working level set to 40 (40000 mSv/hr) using computer in back of Rack A.

UCN BSMs plotted in DCR, watching during kicking. Approved by RSO by email Nov 7, 2024.





Kevin Lucow: 2024-11-12 23:17:39.016421
Default value permanently changed by Safety Group under C2024-11-12-3.
Eric Chapman: 2024-11-12 00:39:46.865944
Re-implement as required up to maximum as specified by RSO. Note that spills can be significantly reduced during 1U operation by reducing ISIS pulser.