AL-ALCW Heat Exchangers H-18 closed and D-17 throttled
Implementation: Number:
2024-12-22 05:10:00 2024-581

Gauhar Hayat

Jas Uppal

Removed
Est. Duration:
16 weeks

Reduced heat load, main magnet is off.

Main magnet back on.

2

SAB3 Al-ALCW Heat Ex. Valve H-18 and D-17.

MCR Defeat Board

SAB3 heat exchangers H-18 closed and D-17 throttled.

Visially confirmed valve position at heat exchangers H-18 and D-17.