Interlock Defeat / Device Disable
Management System v1.5 (Driver)

Accelerator Complex:



Home
List of Defeats   ▸
List of Disables ▸
Fill Out a Defeat
Fill Out a Disable
Add/Modify User
Add/Modify System
Login
Help
Implementation Removal

Interlock Defeat


Vacuum

Lower Alarm limit in EHDT:IM66
Implementation: Number:
2017-04-13 09:30:00 2017-6

Jason Wait

Active
Estimated Duration:
104 weeks

EHDT:IM66 is reading close to the lower alarm limit (1 e^-10 Torr) and is causing nuisance alarms

1

ELCR Defeat board

EHDT:IM66 Higher limit is still in place - Keiko has turned off the alarm through the alarm handler code

Turned EHDT:IM66 off and confirmed high limit alarm was generated





Jason Wait: 2020-11-19 00:41:07.076565
Paper defeat #073
Requested by Brandon H.
Implemented by Keiko E.
Approved by Brandon H. and Dimo Y.

Brandon Humphries: 2020-12-22 09:40:21.744651
Correction: vacuum gauge is EHDT:IMG6