Implementation Removal

Interlock Defeat


Safety

ANM6 and AGM6 (Counts, WARN and TRIP)
Implementation: Number:
2024-03-07 13:15:00 2024-143

Brandon Humphries

Removed
Estimated Duration:
8 weeks

Two radiation monitors (ARIEL Neutron Monitor #6 and ARIEL Gamma Monitor #6) were physically removed to allow for 284' level shielding blocks to be removed (for BL4N work).

2

1- On cork board in back of DCR

1- On safety system box on E-LINAC side of the DCR

Defeat implemented by Kevin Ardron through the RMS program on the safety system console. Counts, WARN and TRIP alarms were all defeated. The defeated RMS devices were physically removed from their location at the 284' level entrance to the E-Hall.

Ignition key is locked out under Disable 2024-142. So radiation sources (beam and RF) can't be turned on. Limit switch for 284' level door also removed, so can't secure the E-Hall.


A2024-03-07-1

2024-142