Interlock Defeat / Device Disable
Management System v2.0 (Driver)
Accelerator Complex:



Home
List of Defeats   ▸
List of Disables ▸
Fill Out a Defeat
Fill Out a Disable
Add/Modify User
Add/Modify System
Login
Help
Implementation Removal

Interlock Defeat


Ion sources and injection BL

Skimmer #7 grounded
Implementation: Number:
2024-05-17 11:15:00 2024-261

Elena Bylinskaia

Removed
Estimated Duration:
5 days

Skimmer #7 went into alarm state with no beam into ISIS BL.

2

SA L1, ISIS ground panel, Skimmer #7 "IN" signal.

Skimmer #7 grounded at ISIS "Ground" panel.

No beam into ISIS beam line. defeat should be removed before beam injection.





Elena Bylinskaia: 2024-05-17 11:21:55.697162
Skimmer #7 went into Alarm state without beam down the injection line. Tried to reset it at Bias box with no luck. Making loud noise in DCR and SA L1. TEMPORARY defeated it, ISIS personnel notified.