Interlock Defeat / Device Disable
Management System v2.0 (Driver)
Accelerator Complex:



Home
List of Defeats   ▸
List of Disables ▸
Fill Out a Defeat
Fill Out a Disable
Add/Modify User
Add/Modify System
Login
Help
Implementation Removal

Interlock Defeat


RF

HESW Spill TC #1 trip (ILTANK,22)
Implementation: Number:
2024-06-30 18:08:00 2024-348

Chris Sooley

Chris Sooley, Ryan Lovelidge
Active
Estimated Duration:
1 weeks

HESW Spill TC #1 (RF,323) has become noisy since cyclotron startup, generating multiple beam trips.

2

DCR defeat board. Main console Rack F.

Implemented by taking ILTANK Element 22 off-scan. HESW TC #1 still provides temperature readback and a warn.

HESW Spill TC #1 (RF,323) still provides temperature readback. ILTANK Element 23 (temperature warn) is still on-scan.

FR# 17120




Sierra Dean: 2024-10-28 00:17:28.863142
Found ILTANK Element #23 off scan since 03-Oct-2024. Although this defeat references Element #23 (Temperature warn) as alternate protection, the alternate protection is actually HESW Spill TC #2, which is active and on scan.
Travis Kurucz: 2024-08-14 14:48:49.170314
Scan re-enabled itself sometime after being taken off scan. Scan re-defeated.
Chris Sooley: 2024-06-30 18:34:57.513046
E-mail has been sent to Yuri regarding erratic behaviour of RF TW#323.