Implementation Removal

Interlock Defeat


Safety

EMBD:LIC2 trip threshold increased from 75 pC to 85 pC
Implementation: Number:
2024-11-14 09:26:00 2024-512

Brandon Humphries

Chris Sooley
Active
Estimated Duration:
20 weeks

Field emission from EINJ and EACA RF is causing very high readings and trips from EMBD:LIC2. BLM team gave the okay to increase the trip threshold by 10 pC (from 75 pC to 85 pC).

2

1-On ESS panel

1-On cork board in the back of the DCR

Controls changed the code in the MPS 01 IOC for the Settings OK threshold for EMBD:LIC2. This means the Settings OK interlock in the EGUN:BIAS and MPS FSD will be OK for the new trip threshold.

BLM will still trip, just at a higher threshold.


A2024-11-14-1