Implementation Removal

Interlock Defeat


Targets

STF Water Jacket H2O Level Sensor BYP-005
Implementation: Number:
2024-12-05 15:08:00 2024-544

Chris Sooley

David Bandiera
Active
Estimated Duration:
3 weeks

STF H2O level sensor readback suddenly dropped to -2.6M

2

1) DCR Defeat board



2) SAB2 Rack 1-A


STF BYP-005 pinned in SAB2 Rack 1-A

STF water jacket Low-Low sensor is still actve. Level being monitored in DCR.





Chris Sooley: 2024-12-05 15:23:31.441347
Approved by Louis Moskven and Steve Sapriken, See E-log entry 2024-12-05 14:50:31