Implementation Removal

Interlock Defeat


Targets

STF leak sensor
Implementation: Number:
2016-11-01 17:15:00 2016-690

Micheal Donohoe

Active
Estimated Duration:
104 weeks

Steve reports sensor is presently NOT installed in nominal location and has possibly failed.

2

1) MCR Defeat Board
2) Door of rack 1A South

Sensor pinned 'OK' on STF Bypass Panel Rack 1A SAB2 (south side).

Associated message also taken off scan: DIS STF,56,12

STF water package level sensors. Confirmed level sensors not defeated.





Micheal Donohoe: 2020-11-14 12:12:58.576769
Original paper defeat #7646.
Requested by Steve Sapriken.
Approved/implemented by Kathleen Genge.

2017-02-06: DF is still required (S.S.)