Targets |
Beamline 2C ignition key removed to lockout cabinet |
Implementation: | Number: |
2023-10-13 13:30:00 | 2023-564 |
Riley Schick-Martin |
|
|
Removed |
Est. Duration: 2 weeks |
STF cannot receive beam until approved by experts and RPG |
Approval granted by RPG and STF experts to run 2C4 or for 2C1 operation |
2 |
On BL2C key in lockout cabinet, DCR defeat board |
Key removed from console and locked in lockout cabinet. |
Blank selected on X2C (foil #14) and confirmed probe cannot be enabled. |
|
|
|
|
Eric Chapman: 2023-10-19 17:03:14.075154
After testing on Oct 19th, suspicion is that a portion of the Reservoir vent line is leaking allowing activated gases to be pulled up through the stack. Suspension of STF operation continues.