Safety

Air Monitor #31 warn limit lowered to 40 KCPM.
Implementation: Number:
2023-08-24 17:15:00 2023-481

Gauhar Hayat

Jas Uppal, Kathleen Genge
Removed
Estimated Duration:
8 weeks

As instructed by Head of RPG.

2

RMS Computer on back of Rack A in MCR


MCR Defeat Board

Via RMS computer in back of Rack A in MCR

Encompasses previous Air Monitor Warn Limit, as it has been lowered. Warn still active.





Kathleen Genge: 2023-08-29 15:37:31.046283
From: Kevin Ardron
Sent: Tuesday, August 29, 2023 12:32 PM
To: Kathleen Genge ; Rock Neveau ; Bradley Noakes
Cc: Ricardo Pedrosa
Subject: Re: Warn Limits and Defeats for AM#31 and #32

Hello All,

The Default Warn Level for AM#31 has been changed to 40 kcpm.

Kathleen, you may remove the defeat you have in place as the Working Warn Level is now the same as the Default.