Implementation Removal

Interlock Defeat


Targets

2A3COL-TC3
Implementation: Number:
2021-06-15 12:30:00 2021-203

Riley Schick-Martin

Active
Estimated Duration:
12 weeks

TC is reading -95 deg. Defeat approved by Alex Gottberg.

2

DCR defeat board. 2A electrical room.

Circuit pinned in 2A electrical room.

Other TC's are still functioning.





Riley Schick-Martin: 2022-07-04 09:29:40.933439
As per Carla Babcock, there is currently no plan to repair the associated fault #14028. This defeat is to be extended indefinitely.