Interlock Defeat / Device Disable
Management System v1.5 (Driver)

Accelerator Complex:



Home
List of Defeats   ▸
List of Disables ▸
Fill Out a Defeat
Fill Out a Disable
Add/Modify User
Add/Modify System
Login
Help
Implementation Removal

Interlock Defeat


Optics

1AQ15 ground current detection circuit bypassed
Implementation: Number:
2017-08-22 18:15:00 2017-2

Micheal Donohoe

Active
Estimated Duration:
104 weeks

Ground currents in 1AQ15 are low. With 1AQ15 current at ~750A, ground current is approximately 4A.

2

1) MCR Defeat Board

2) 1AQ15 PS

Circuit bypassed in the 1AQ15 power supply.

None described on original paper defeat.





Micheal Donohoe: 2020-11-14 12:53:02.98127
Original paper defeat #8025.
Requested/approved by Doug Preddy.
Implemented by Dan Louie.

Jas Uppal: 2023-04-27 12:03:18.328807
Defeat still active. Ground fault still present and defeated as reported by Dan Louie.